UNDERSTANDING AND MINIMIZING THE RISK OF THE GROWING PROBLEM OF MOLD IN NEW HOMES Is the home you buy susceptible to Mold Growth?
"A California Builder's Guide to Reducing Mold Risk" FREE 61-page PDF- April 12th, 2006
Database Development of Mold Incidences in California Homes Literature Review Summary Report Major Findings The interviews with experts in the field provided an up-to-date sampling of the most relevant issues related to moisture intrusion in building assemblies. The (mostly peer reviewed) literature created a supporting foundation of information detailing backgroundon the moisture intrusion issues cited by the experts in the field, as well as other issues. Interviews The major water intrusion issues cited in the 16 interviews include: Bulk Water -- Improper lot grading and/or settling create slopes toward foundations and allow water to intrude into slabs, crawlspaces or basements; irrigation systems overspray water and repeatedly wet foundations and walls; and roof downspouts are inadequately separated away from homes and deposit water near foundations instead of to a properly sloped grade. Roof Eaves -- Roof eaves lack sufficient extensions outward and permit rain, especially wind driven rain, to soak exterior porous (brick, stucco, wood, etc.) facades. Vapor Barriers -- Barriers are sometimes incorrectly applied or of the wrong type, depending on climate, and allow moisture to be trapped or build up in walls. Walls need to be able to breathe. Window Detailing in Wall and Roof Penetrations -- o Builders and subcontractors lack sufficient training for proper installation of windows (and flashing). o Building codes lack standardized window installation practices. o Standards are non-existent for installation of building membranes and flashings with windows. o Standards for windows, building membranes, and flashing are outdated (post WW-II ASTM standards) and need to be modernized. o Trade organizations for fenestration, building membranes, and flashing are needed to foster these training, standard, and code activities.⢠Interior Moisture/HVAC -- o Houses are too tight for natural ventilation to be effective. Mechanical outside air (OA) ventilation is needed. o Architects and engineers need to be educated on ventilation issues and mechanical ventilation options. o Oriented Strand Board (OSB) is often gets wet during construction and then is not adequately dried before wall and roof construction is completed. o Some newer paints have much less tolerance to mold growth than paints manufactured 20-25 years ago. o DHW heaters, AC coils/drain pans, and ductwork, are placed in attics where leaks can go unnoticed for some time until after substantial damage is done. o Baths and kitchens do not have properly sized exhaust fans that run until moisture levels are reduced to desired humidity levels. Fan operation needs to be automated (based on humidity level) to remove the human factor. Most of these fans are too noisy and people are annoyed and limit their operation. o Wet spray cellulose, if used, Is not allowed to dry sufficiently. Moisture content needs to be checked before closing drywall. o Moisture content in wood framing is often to high before closing in the walls. Moisture content needs to be checked before closing drywall and should not be higher than 19%. Miscellaneous o An homeownersâ manual needs to be developed that would address some of the maintenance issues that could prevent mold incidences over the life of a house. o A buildersâ manual needs to be developed that offers a "systems approach" to ensuring quality and managing risk during construction. For example, utilizing a series of checkpoints established by extensive litigation and failure analysis background, specially trained inspectors can check for specific, known anomalies in the building assemblies at greatest risk of water damage and mold formation. o Construction sequencing is a clear issue with poor scheduling leading to unprotected building materials getting soaked with rain/snow on the job site. o Elastomeric paints for stucco to limit cracking and water intrusion need to be utilized.
Literature
A total of 85 literature reviews were completed based on extensive input from the project team and expert interviewees. A survey was also conducted using key words on a variety of search engines, including major commercial and university library based search engines. The following additional keywords to Table 1 were included in, but not limited to, the search: moisture intrusion, residential, homes, and California. The search produced many additional pieces of literature from a variety of sources from trade journals and magazines to product and material organizations.
Some literature provided the scientific and engineering basis for moisture migration in buildings, and ultimately the understanding to manage moisture in homes.
Many of the pieces of literature cited established the methods by which moisture travels: ⢠Pressure differential ⢠Temperature differential ⢠Capillary action ⢠Spills/leaks ⢠Diffusion
Other literature detailed the points at which traveling moisture intrudes into buildings and its assemblies. The following moisture intrusions problem areas were mentioned frequently in the literature. Common moisture intrusion points are:
⢠Penetrations in walls and roofs: windows, doors, skylights, piping through walls, ductwork through walls and ceilings ⢠Roofs with improper installation of flashing, or gutters not working properly ⢠Surface or ground water pooling from improper grading, irrigation system overspray, and improper placement of downspouts. ⢠Interior moisture buildup due to over crowding, improper exhaust venting (bathrooms, kitchen, and laundry), too low of a cooling temperature set point, inadequate removal of moisture (insufficient dehumidification). ⢠Attic/crawlspace moisture from leaky HVAC ducts, condensation on cooler surfaces, improper ventilation of attic/crawl spaces. ⢠Improperly installed vapor and air barriers improperly installed. Proper placement of air barriers is important to allow building assemblies to dry out. ⢠Infiltration of moist air when leaky HVAC ducts cause pressure differentials, leading to outside air being drawn in to building, and oversized air conditioning equipment leading to short cycling that reduces the AC equipment ability to dehumidify.
Potential solutions that were cited for moisture problems are: ⢠Use materials that are not prone to moisture build-up and mold formation: no vinyl wallpaper, etc. ⢠Provide proper air barrier placement for the building assembly to dry out. ⢠Provide eaves with at least 18 inches overhang, and do not start siding within 8 inches of the ground/soil. ⢠Increase the cooling set point temperature, and allow the air to flow around the entire space (well mixed conditions). Furniture can block airflow to corners, leading to cold spots and moisture condensation on cooler, dark surfaces. Provide supplemental dehumidification in addition to air conditioning. ⢠Make sure that flashing is properly installed everywhere, particularly at doors and windows. ⢠Venting of crawlspaces depends on climate: hot humid climates do not necessarily benefit from natural ventilation of crawlspaces.
There have been several field studies of moisture and mold in manufactured housing, but not as much for single-family residences, especially in warmer climates dealing with summer cooling moisture problems. Future researchers are encouraged to update this literature survey by searching for the latest literature related to field work on moistureproblems in single family residences, especially in cooling dominated locations. The existing field data for manufactured homes, and single family homes in heating dominated climates, is best summarized in the 1994 ASTM Manual 18 on Moisture Control in Buildings [R84] from the literature survey. See full pdf report: Database Development of Mold Incidences in California Homes
|
|
|